Auto Tuning Instructions for Hot Chamber Punch Control - OMRON E5CC

MODEL: OMRON E5CC for New HCP Punch and Digital HCP Controller

The following procedure MUST BE FOLLOWED whenever installing a new Hot Chamber Punch (HCP) Punch, new Digital HCP Controller, or have unstable HCP punch temperatures.


A. Turn off the Digital HCP Controller

B. Stop the machine from running

  • If the machine is OFF, turn it ON;

  • Warm up the machine jaws or carriages to the desired temperature

C. Install new HCP Punch

  • Prevent punch cable shaking by using all cable clamps

D. Verify the machine jaws are at the desired temperature and steady

E. DO NOT run the machine

F. Turn ON the Digital HCP Controller

G. Set the punch temperature to the desired temperature

  • Use the two arrows UP and DOWN

H. Press and hold the PF SHIFT for 3 seconds, until the display

screen shows “TUNE”

  • Release the button

I. The punch temperatures will increase and digress several times.

  • These procedures will take approximately 5 - 10 minutes

  • Wait until the “TUNE” disappears

J. The temperature reading should be steady

K. Run the machine


Download these instructions or contact us inquiry@lakotool.com or +1 (419) 662-5626

Procedure-Auto_Tuning-Hot_Chamber_Punch_
.
Download • 239KB