PUNCH

LED Control Display Off


for HCP Punch and Digital Controller

  • Power Switch at OFF position
  • Power cord not plugged
  • Power outlet OFF or NO power out
  • 0.5 Amp hot punch controller fuse burn out
Still experiencing a challenge? Please contact our office. Email: inquiry@lakotool.com Phone: +1 (419) 662-5626




Punch Heater Not Working / SUB 2 Alarm LED Light Indicator ON


for HCP Punch and Digital Controller

  • Hot punch Amphenol connector not connected
  • 1.25 Amps fuse burn out for 150 watts hot punch
  • 2.5 Amps fuse burn out for 250 watts hot punch
  • 4.5 Amps fuse burn out for 500 watts hot punch
  • Hot punch heater wires disconnected from male Amphenol connector
  • Hot punch heater failure
Still experiencing a challenge? Please contact our office. Email: inquiry@lakotool.com Phone: +1 (419) 662-5626




LED Screen Shows SERR Code


for HCP Punch and Digital Controller

  • Hot punch Amphenol connector not connected to the controller
  • TC or RTD sensor wire disconnected from male Amphenol connector
  • TC or RTD sensor failure
Still experiencing a challenge? Please contact our office. Email: inquiry@lakotool.com Phone: +1 (419) 662-5626




SUB 1 Alarm LED Light ON /Auto Tune HI/LO Indicator Light ON or Both Flashing


for HCP Punch and Digital Controller

  • Do auto tune to the hot punch controller (Please follow auto tune procedures)
  • The PV (point variable) temperature lower or higher then SV (set variable) temperature (Our factory default deviation is 5 degree for both HI /Low alarm)
  • Adjust the SUB 1 alarm temperature deviation by setting the alarm upper limit (H) and Alarm lower limit (L) to the prefer value up to your application temperature alarm requirement (read quick punch temperature control setup guide)
Still experiencing a challenge? Please contact our office. Email: inquiry@lakotool.com Phone: +1 (419) 662-5626




SUB 2 Alarm LED Light Indictor ON Hot Punch Situation Is Hot


for HCP Punch and Digital Controller

  • Hot Punch temperature PV (point variable) lower than the SV (set variable). Our factory default downward deviation is 10 degree below the SV (Set variable).
  • Adjust the SUB 2 alarm downward temperature deviation by setting the alarm lower limit to the prefer value up to the application temperature alarm requirement, (read quick punch temperature control setup guide)
Still experiencing a challenge? Please contact our office. Email: inquiry@lakotool.com Phone: +1 (419) 662-5626




Hot Punch Controller Function Stop /STOP LED Light Indicator ON


for HCP Punch and Digital Controller

  • HOT punch controller at STOP MODE.
  • Switch the program Mode from STOP to RUN (read quick punch temperature control setup guide)
Still experiencing a challenge? Please contact our office. Email: inquiry@lakotool.com Phone: +1 (419) 662-5626





KNIVES / ANVILS

Premature knife wear?


Always change the anvil when changing the knife. Still experiencing a challenge? Please contact our office. Email: inquiry@lakotool.com Phone: +1 (419) 662-5626





SEAL

Better Seal


For better seals... Always keep the seal form knife and anvil free of debris